High Frequency Noise Param. Measurement System
Name
High Frequency Noise Parameter Measurement System
Number
HF-004
Location
Hsinchu
Class
High-Frequency Measurement
Access Level
B2
Contact
Mr. Lin 03-5773693 #7774
E-mail
Booking Method
Self-booking Assisted Booking User Self-service
Last Update
2025.01.09
Introduction
The system is utilized to acquire the noise parameters such as NFmin, Rn, and Γopt that represent the noises generated with different impedance matches.
Service
- Frequency Range:
- 1 GHz~18 GHz (ATN NP5B / HP 85122A)
- 18 GHz~65 GHz (Auriga Noise Parameter Measurement System) - DUT: HEMT,HBT,BJT,MOSFET, etc
- Measurement: Noise figure, S-parameter and IV
Equipment
- 1 GHz ~ 18 GHz (ATN NP5B / HP 85122A)
- NP5 Wafer Probe Test Set
- Remote Receiver Module(RRM-5) Frequency range:1 GHz ~ 18 GHz
- Mismatch Noise Module(MNS-5) Frequency range:1 GHz ~ 18 GHz
- Network Analyzer(HP 8510C) Frequency range:45 MHz~ 20 GHz
- DC Source /Monitor(HP 4142B)
- Synthesized Sweeper(HP 83620B) Frequency range:10 MHz ~ 20 GHz
- S-Parameters Test Set(HP 8514B) Frequency range:45 MHz ~ 20 GHz
- 18 GHz ~ 65 GHz (Auriga Noise Parameter Measurement System)
- PNA (Agilent E8361A) Frequency range:10 MHz ~ 67 GHz
- Noise Figure Meter (Agilent N8975A) Frequency range:10 MHz ~ 26.5 GHz
- Signal Generator(HP 83630B) Frequency range:10 MHz ~ 26.5 GHz
- DC Source /Monitor(HP 4142B)
- Tuner(Focus Model 67260)
- Pre-Amp(Auriga AU3310)
- Down Converter(Auriga AU3309)
- PNS Controller(Auriga AU3101)
Software
- 1 GHz ~ 18 GHz (ATN NP5B / HP 85122A)
- HP Basic Based Software
- 18 GHz ~ 65 GHz (Auriga Noise Parameter Measurement System)
- HT Basic Based Software
Supplementary Information
Price ListQ&A
Notice
Users without attending their session will still get charged according to the Price List.【Self-booking】 Users should attend their reserved session. If cancellation is necessary, please complete it on the official website at least 3 days before.
【Assisted Booking】 Users should arrive as scheduled. If a reschedule is required, please inform the assigned engineer in advance.
【User Self-service】 Please use the system within the reserved session after reservation.
Instrument Reservation Procedure
Users can initiate the reservation process by visiting the TSRI homepage.Navigate to 'Measurement Services' and select the desired reservation item.
Log in to the reservation system to proceed with the reservation.
- 【Self-booking】Please make a reservation on the available pages.
- 【Assisted Booking】After applying and receiving approval from TSRI engineers, the Booking System will send notifications containing the data and time of appointments.
- Users are required to arrive at the laboratory on time. Absent users will be charged a minimum of one unit of time usage fee.
- Upon the completion of measurement appointments, users will receive completion notifications via email. If no objections are raised within the specified timeframe, please complete payment by the expiry date. If emails are not received, please contact TSRI customer service.
- All instruments or accessories must be returned to their original locations to keep the order and convenience for the next users.
- In the event of any damaged, missing, dysfunctional, or non-operational instruments or accessories, please promptly notify the engineers.
- Users are not permitted to use laboratory computers or remotely access their personal computers. If computer access is necessary, please contact the laboratory assistant or engineers.
- The laboratory operates during the hours of 9:00 AM to 12:00 PM and 1:00 PM to 5:00 PM. During the lunch break, the laboratory is closed, and the users are advised to wait in the hallway.
- Food and beverages are strictly prohibited within the laboratory.
- TSRI reserves all the rights to approve the usage of all laboratory equipment and resources.