40GHz Measurement System

Name
40 GHz Measurement System
Number
HF-101
Location
Hsinchu
Class
High-Frequency Measurement
Access Level
B4
Contact
Ms. Yang   03-5773693 #7667
Booking Method
Self-booking   Assisted Booking   User Self-service
Last Update
2025.01.09
 

Introduction

The HF-101 Measurement System provides S-parameter, linearity/non-linearity testing, noise figure, and 2 GHz bandwidth modulation services for RFICs(Radio Frequency Integrated Circuits), including LNA (Low Noise Amplifier),VGA (Variable Gain Amplifier), PA (Power Amplifier), mixer, switch, phaseshifter, filter, and more.

Service

RFIC Measurement
  1. Frequency Range: 10 MHz ~ 67 GHz
  2. DUT: LNA, PA, VGA, Mixer, Phase Shifter, Filter, Switch, etc.
  3. Measurement: S-parameter, RF Power, Spectrum, P1dB, IIP3, Conversion-Gain, Isolation, Noise Figure.
Modulation Measurement
  1. Modulation Type:ASK、QPSK QAM1024、Custom OFDM
  2. Measurement Item: EVM、CCDF、ACPR、Constellation Diagram
 

Equipment

  1. 4-Port Network Analyzer(Keysight N5245B): 10 MHz ~ 50 GHz
  2. Signal Generator(Agilent E8527D): 250 KHz~40 GHz*2
  3. Signal Generator(Agilent E8527D): 250 KHz~67 GHz
  4. Spectrum Analyzer(Agilent E4448A): 3 Hz~50 GHz
  5. 5. Power Meter&Senser(Agilent E8488A): 10 MHz~67 GHz
  6. Power Meter&Senser(Agilent E4413A): 50 MHz~26.5 GHz*2
  7. Noise Figure Analyzer(Agilent N8975A): 10 MHz~26.5 GHz
  8. Noise Source(Agilent 346C) : 10 MHz~26.5 GHz*2
  9. Noise Source(Agilent N4002A) : 10 MHz~26.5 GHz
  10. Noise Source(Agilent 346CK01) : 1G Hz~50 GHz
  11. Keysight E8267D Signal Generator : 250 KHz~44 GHz
  12. Keysight M8190 Arbitrary Waveform Generator : 12 GHz Sampling Rate
  13. Keysight DSA-Z334A Oscilloscope : 63 GHz
  14. Keysight N9041B Signal Analyzer : 2 Hz~110 GHz
 

Software

  1. Cascade Wincal RF Calibration Tool
  2. 1. Keysight 89601B Vector Signal Analyzer Software
  3. 2. Keysight K3101A Signal Optimizer Software
 

Supplementary Information

Note1: Please contact engineer for the power range of linearity measurement of your DUT.
Price List
Q&A
 

Notice

Users without attending their session will still get charged according to the Price List.
【Self-booking】 Users should attend their reserved session. If cancellation is necessary, please complete it on the official website at least 3 days before.
【Assisted Booking】 Users should arrive as scheduled. If a reschedule is required, please inform the assigned engineer in advance.
【User Self-service】 Please use the system within the reserved session after reservation.

Instrument Reservation Procedure

Users can initiate the reservation process by visiting the TSRI homepage.
Navigate to 'Measurement Services' and select the desired reservation item.
Log in to the reservation system to proceed with the reservation.
 
 
  1. 【Self-booking】Please make a reservation on the available pages.
  2. 【Assisted Booking】After applying and receiving approval from TSRI engineers, the Booking System will send notifications containing the data and time of appointments.
  3. Users are required to arrive at the laboratory on time. Absent users will be charged a minimum of one unit of time usage fee.
  4. Upon the completion of measurement appointments, users will receive completion notifications via email. If no objections are raised within the specified timeframe, please complete payment by the expiry date. If emails are not received, please contact TSRI customer service.
  5. All instruments or accessories must be returned to their original locations to keep the order and convenience for the next users.
  6. In the event of any damaged, missing, dysfunctional, or non-operational instruments or accessories, please promptly notify the engineers.
  7. Users are not permitted to use laboratory computers or remotely access their personal computers. If computer access is necessary, please contact the laboratory assistant or engineers.
  8. The laboratory operates during the hours of 9:00 AM to 12:00 PM and 1:00 PM to 5:00 PM. During the lunch break, the laboratory is closed, and the users are advised to wait in the hallway.
  9. Food and beverages are strictly prohibited within the laboratory.
  10. TSRI reserves all the rights to approve the usage of all laboratory equipment and resources.