220 GHz S-Parameter Measurement System

Name
220 GHz S-Parameter Measurement System
Number
HF-014
Location
Hsinchu
Class
High-Frequency Measurement
Access Level
B4
Contact
Mr. Teng   03-5773693 #7633
Booking Method
Self-booking   Assisted Booking    User Self-service
Last Update
2025.01.09
 
 

Introduction

The system provides 2-Port S-parameter measurement from 140 GHz to 220 GHz.


Service

  1. Frequency Range: 140 GHz~220 GHz
  2. DUT: MOSFET, BJT, HBT, HEMT, LNA, PA, Mixer, Filter, etc.
  3. Measurement: 2-Port Scattering Parameters
 

Equipment

  1. 140 GHz ~ 220 GHz
  2. Vector Network Analyzer (Keysight PNA-X N5242B) : 10 MHz~26.5 GHz
  3. Millimeter Head Controller (Agilent N5262A)
  4. G-band Frequency Extender (OML V05VNA2-T/R) : 140 GHz~220 GHz
  5. DC source/Monitor (HP4142B)
 

Software

  1. FormFactor WinCal XE
  2. Keysight IC-CAP

Supplementary Information

Note1: In addition to the On-Wafer measurement type, this system also provides the Waveguide measurement type.
Price List
Q&A
 

Notice

Users without attending their session will still get charged according to the Price List.
【Self-booking】 Users should attend their reserved session. If cancellation is necessary, please complete it on the official website at least 3 days before.
【Assisted Booking】 Users should arrive as scheduled. If a reschedule is required, please inform the assigned engineer in advance.
【User Self-service】 Please use the system within the reserved session after reservation.

Instrument Reservation Procedure

Users can initiate the reservation process by visiting the TSRI homepage.
Navigate to 'Measurement Services' and select the desired reservation item.
Log in to the reservation system to proceed with the reservation.
 
 
  1. 【Self-booking】Please make a reservation on the available pages.
  2. 【Assisted Booking】After applying and receiving approval from TSRI engineers, the Booking System will send notifications containing the data and time of appointments.
  3. Users are required to arrive at the laboratory on time. Absent users will be charged a minimum of one unit of time usage fee.
  4. Upon the completion of measurement appointments, users will receive completion notifications via email. If no objections are raised within the specified timeframe, please complete payment by the expiry date. If emails are not received, please contact TSRI customer service.
  5. All instruments or accessories must be returned to their original locations to keep the order and convenience for the next users.
  6. In the event of any damaged, missing, dysfunctional, or non-operational instruments or accessories, please promptly notify the engineers.
  7. Users are not permitted to use laboratory computers or remotely access their personal computers. If computer access is necessary, please contact the laboratory assistant or engineers.
  8. The laboratory operates during the hours of 9:00 AM to 12:00 PM and 1:00 PM to 5:00 PM. During the lunch break, the laboratory is closed, and the users are advised to wait in the hallway.
  9. Food and beverages are strictly prohibited within the laboratory.
  10. TSRI reserves all the rights to approve the usage of all laboratory equipment and resources.